Application:
Nominal 37mm proprietary fire doors.
This sealing combination suitable for typical 60 minute fire-rated entry doors & passage doors for apartments, hotels, motels & aged care facilities, where a minimum sound insulation of Rw30 is required.
Approvals:
Tests were performed in accordance with Australian Standard AS1191:2002 & ISO 140.3:1195.
AS1530 Part 4 fire tests with Proprietary fire doors providing up to 2 hours fire resistance, in compliance with AS1905 Part 1.
Proof:
Kilargo has conducted an extensive testing program of door panels and door seals at the N.A.T.A accredited Acoustic Facilities of RMIT University Melbourne.
Door Thickness | STC Rating | Rw Rating |
---|---|---|
Nom. 37mm | 30 | 30 |
For more information and copies of relevant certificates contact Kilargo